Density Test Report

Date :03/28/2026
Project No :2024C296
Client Company :Artisan
Arrival Time :03/28/2026 08:00
Onsite Hours :01:00
Name of the Project :Heritage Pointe - Footing Inspections
Project Location :Villa Rica
Weather :Sunny
Departure Time :03/28/2026 09:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
03/28/2026 1 23.4 94.1 2026-077 95.8 20.0 98.2 95 D6938 Pass
Location : Lot #109, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :77-19952
03/28/2026 2 22.4 95.5 2026-077 95.8 20.0 99.7 95 D6938 Pass
Location : Lot #109, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :77-19952
03/28/2026 3 21.6 91.1 2026-077 95.8 20.0 95.1 95 D6938 Pass
Location : Lot #109, Elv/Depth :at finished grade
Comment : Gauge Serial No. :77-19952
03/28/2026 4 21.2 91.3 2026-077 95.8 20.0 95.3 95 D6938 Pass
Location : Lot #109, Elv/Depth :at finished grade
Comment : Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, March 28, 2026
Reviewer Name / DateKenneth Mosman, March 30, 2026