- Density Test Report Report ID: 91919
- Edit Download Report
Density Test Report
Date :03/26/2026
Project No :2025C211
Client Company :Pulte
Arrival Time :03/26/2026 10:00
Onsite Hours :06:30
Name of the Project :Haley's Bluff - Philadelphia Rd.
Project Location :Jasper
Weather :Sunny
Departure Time :03/26/2026 16:30
ASEC Technician Name :Sean Willett
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 03/26/2026 | 1 | 14.9 | 125.5 | 2025-055 | 107.3 | 15.5 | 101.8 | 95 | D6938 | Pass |
| Location : | Retaining wall 1, Elv/Depth :7 baskets | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 03/26/2026 | 2 | 19.6 | 98.0 | FP 2 | 100.0 | 18.5 | 98.0 | 95 | D6938 | Pass |
| Location : | Retaining wall 1, Elv/Depth :7 baskets | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 03/26/2026 | 3 | 19.8 | 100.3 | FP 2 | 100.0 | 18.5 | 100.3 | 95 | D6938 | Pass |
| Location : | Retaining wall 1, Elv/Depth :7 baskets | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 03/26/2026 | 4 | 20.2 | 95.1 | FP 2 | 100.0 | 18.5 | 95.1 | 95 | D6938 | Pass |
| Location : | Retaining wall 1, Elv/Depth :7 baskets | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 03/26/2026 | 5 | 24.5 | 93.5 | FP 2 | 100.0 | 18.5 | 93.5 | 95 | D6938 | Fail |
| Location : | Retaining wall 1, Elv/Depth :7 baskets | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 03/26/2026 | 6 | 20.1 | 95.5 | FP 2 | 100.0 | 18.5 | 95.5 | 95 | D6938 | Pass |
| Location : | Retaining wall 1, Elv/Depth :7 baskets | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 03/26/2026 | 7 | 19.9 | 95.3 | FP 2 | 100.0 | 18.5 | 95.3 | 95 | D6938 | Pass |
| Location : | Retaining wall 1, Elv/Depth :7 baskets | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 03/26/2026 | 8 | 21.9 | 90.6 | FP 2 | 100.0 | 18.5 | 90.6 | 95 | D6938 | Fail |
| Location : | Retaining wall 1, Elv/Depth :8 baskets | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 03/26/2026 | 9 | 23.8 | 90.5 | FP 2 | 100.0 | 18.5 | 90.5 | 95 | D6938 | Fail |
| Location : | Retaining wall 1, Elv/Depth :8 baskets | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 03/26/2026 | 10 | 29.6 | 80.5 | FP 2 | 100.0 | 18.5 | 80.5 | 95 | D6938 | Fail |
| Location : | Retaining wall 1, Elv/Depth :8 baskets | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 03/26/2026 | 11 | 25.2 | 86.6 | FP 2 | 100.0 | 18.5 | 86.6 | 95 | D6938 | Fail |
| Location : | Retaining wall 1, Elv/Depth :8 baskets | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
Technician Signature / DateSean Willett, March 26, 2026
Reviewer Name / DateKenneth Mosman, March 31, 2026