- Home
- Density Test Report Report ID: 92280
- Edit Download Report
Density Test Report
Date :04/02/2026
Project No :2025C186
Client Company :CWM
Arrival Time :04/02/2026
Onsite Hours :
Name of the Project :Tom B. David Airport - Rehab Parallel Taxiway & Terminal Apron
Project Location :Calhoun
Weather :overcast
Departure Time :04/02/2026
ASEC Technician Name :Russell Hendrix
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 04/02/2026 | 1 | 3.8 | 147.6 | 2025-065 | 150.1 | 5.3 | 98.3 | 98 | D6938 | Pass |
| Location : | A3 Taxiway Center, Elv/Depth :Top of subgrade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 04/02/2026 | 2 | 3.5 | 143.3 | 2025-065 | 150.1 | 5.3 | 95.5 | 98 | D6938 | Fail |
| Location : | A# to A4 connector Center, Elv/Depth :Top of Subgrade | |||||||||
| Comment : | UES stated the test result was acceptable | Gauge Serial No. :38069 | ||||||||
| 04/02/2026 | 3 | 3.7 | 148.2 | 2025-065 | 150.1 | 5.3 | 98.7 | 98 | D6938 | Pass |
| Location : | A4 Taxiway, Elv/Depth :Top of subgrade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
Technician Signature / DateRussell Hendrix, April 2, 2026
Reviewer Name / DateKenneth Mosman, April 08, 2026