Skip to content

Density Test Report

Date :03/30/2026
Project No :2026C125
Client Company :Lewis Contracting
Arrival Time :03/30/2026 15:00
Onsite Hours :01:00
Name of the Project :Pittman Park - Garibaldi St. Stormwater
Project Location :Atlanta
Weather :Sunny
Departure Time :03/30/2026 16:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
03/30/2026 1 22.3 95.5 Proctor 1 104.9 19.8 91.0 95 D6938 Fail
Location : Sewer line s-1 - s-3, Elv/Depth :4 feet over pipe
Comment : Gauge Serial No. :77-19952
03/30/2026 2 21.5 101.2 Proctor 1 104.9 19.8 96.5 95 D6938 Pass
Location : Sewer line s-1 - s-3, Elv/Depth :4 feet over pipe
Comment : Gauge Serial No. :77-19952
03/30/2026 3 20.2 104.5 Proctor 1 104.9 19.8 99.6 95 D6938 Pass
Location : Sewer line s-1 - s-3, Elv/Depth :4 feet over pipe
Comment : Gauge Serial No. :77-19952
03/30/2026 4 19.7 100.0 Proctor 1 104.9 19.8 95.3 95 D6938 Pass
Location : Sewer line s-1 - s-3, Elv/Depth :4 feet over pipe
Comment : Gauge Serial No. :77-19952
03/30/2026 5 18.9 102.4 Proctor 1 104.9 19.8 97.6 95 D6938 Pass
Location : Sewer line s-1 - s-3, Elv/Depth :4 feet over pipe
Comment : Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, March 30, 2026