Skip to content

Density Test Report

Date :04/08/2026
Project No :2025C211
Client Company :Pulte
Arrival Time :04/08/2026 07:00
Onsite Hours :04:00
Name of the Project :Haley's Bluff - Philadelphia Rd.
Project Location :Jasper
Weather :Sunny
Departure Time :04/08/2026 11:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/08/2026 1 19.4 102.1 2025-055 107.3 15.5 95.2 95 D6938 Pass
Location : Retaining wall 1, Elv/Depth :1 basket
Comment : Gauge Serial No. :77-19952
04/08/2026 2 20.7 103.1 2025-055 107.3 15.5 96.1 95 D6938 Pass
Location : Retaining wall 1, Elv/Depth :1 basket
Comment : Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, April 8, 2026
Reviewer Name / DateKenneth Mosman, April 14, 2026