- Home
- Density Test Report Report ID: 93532
- Edit Download Report
Density Test Report
Date :04/20/2026
Project No :2026C125
Client Company :Lewis Contracting
Arrival Time :04/20/2026 14:00
Onsite Hours :02:00
Name of the Project :Pittman Park - Garibaldi St. Stormwater
Project Location :Atlanta
Weather :Sunny
Departure Time :04/20/2026 16:00
ASEC Technician Name :Sean Willett
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 04/20/2026 | 1 | 17.8 | 100.6 | Proctor 1 | 104.9 | 19.8 | 95.9 | 98 | D6938 | Fail |
| Location : | Storm line in parking lot, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 04/20/2026 | 2 | 15.1 | 100.1 | Proctor 1 | 104.9 | 19.8 | 95.4 | 98 | D6938 | Fail |
| Location : | Storm line in parking lot, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
Technician Signature / DateSean Willett, April 20, 2026
Reviewer Name / DateKenneth Mosman, April 27, 2026