Skip to content

Density Test Report

Date :04/22/2026
Project No :2023C159
Client Company :CW Matthews
Arrival Time :04/22/2026 18:30
Onsite Hours :12:30
Name of the Project :Airfield Repairs 2021-23
Project Location :HJAIA, Atlanta, GA
Weather :clear
Departure Time :04/23/2026 07:00
ASEC Technician Name :Samara Simha Reddy Kandi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/22/2026 1 7.1 115.4 2026-120 125.2 9.7 92.2 90 D6938 Pass
Location : Area 2, Elv/Depth :6 feet below finished grade
Comment : Gauge Serial No. :91487
04/22/2026 2 7.9 115.0 2026-120 125.2 9.7 91.9 90 D6938 Pass
Location : Area 2, Elv/Depth :6 feet below finished grade
Comment : Gauge Serial No. :91487
04/23/2026 3 7.4 121.7 2026-120 125.2 9.7 90.5 90 D6938 Pass
Location : Area 2, Elv/Depth :4.5 feet below finished grade
Comment : Gauge Serial No. :91487
04/23/2026 4 7.9 114.1 2026-120 125.2 9.7 91.1 90 D6938 Pass
Location : Area 2, Elv/Depth :4.5 feet below finished grade
Comment : Gauge Serial No. :91487
04/23/2026 5 6.2 120.8 2026-120 125.2 9.7 90.8 90 D6938 Pass
Location : Area 2, Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :91487
04/23/2026 6 6.8 112.9 2026-120 125.2 9.7 90.2 90 D6938 Pass
Location : Area 2, Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :91487
04/23/2026 7 6.4 113.4 2026-120 125.2 9.7 90.6 90 D6938 Pass
Location : Area 2, Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :91487
04/23/2026 9 5.3 114.4 2026-118 124.3 8.9 92.0 95 D6938 Fail
Location : Area 5, Elv/Depth :at finished grade
Comment : Gauge Serial No. :91487
04/23/2026 10 5.9 121.8 2026-118 124.3 8.9 92.5 95 D6938 Fail
Location : Area 5, Elv/Depth :at finished grade
Comment : Gauge Serial No. :91487
Technician Signature / DateSamara Simha Reddy Kandi, April 22, 2026
Reviewer Name / DateKenneth Mosman, May 11, 2026