Skip to content

Density Test Report

Date :04/25/2026
Project No :2023C159
Client Company :CW Matthews
Arrival Time :04/25/2026 19:30
Onsite Hours :10:30
Name of the Project :Airfield Repairs 2021-23
Project Location :HJAIA, Atlanta, GA
Weather :clear
Departure Time :04/26/2026 06:00
ASEC Technician Name :Samara Simha Reddy Kandi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/25/2026 1 16.1 101.6 Field Proctor 110.4 17.1 92.0 90 D6938 Pass
Location : Area 4, Elv/Depth :5.5 feet below finished grade
Comment : Gauge Serial No. :38069
04/25/2026 2 16.5 105.8 Field Proctor 110.4 17.1 95.8 90 D6938 Pass
Location : Area 4, Elv/Depth :5.5 feet below finished grade
Comment : Gauge Serial No. :38069
04/26/2026 3 15.6 105.6 Field Proctor 110.4 17.1 95.7 90 D6938 Pass
Location : Area 4 , Elv/Depth :3.5 feet below finished grade
Comment : Gauge Serial No. :38069
04/26/2026 4 15.6 107.5 Field Proctor 110.4 17.1 97.4 90 D6938 Pass
Location : Area 4, Elv/Depth :3.5 feet below finished grade
Comment : Gauge Serial No. :38069
04/26/2026 5 18 104.2 Field Proctor 110.4 17.1 94.4 90 D6938 Pass
Location : Area 4, Elv/Depth :2.5 feet below finished grade
Comment : Gauge Serial No. :38069
04/26/2026 6 14.6 125.2 Field Proctor 110.4 17.1 98.9 90 D6938 Pass
Location : Area 4, Elv/Depth :2.5 feet below finished grade
Comment : Gauge Serial No. :38069
04/26/2026 7 12.4 123.1 Field Proctor 110.4 17.1 99.2 90 D6938 Pass
Location : Area 4, Elv/Depth :1.5 feet below finished grade
Comment : Gauge Serial No. :38069
04/26/2026 8 17.4 106.0 Field Proctor 110.4 17.1 96.0 90 D6938 Pass
Location : Area 4, Elv/Depth :1.5 feet below finished grade
Comment : Gauge Serial No. :38069
Technician Signature / DateSamara Simha Reddy Kandi, April 25, 2026
Reviewer Name / DateKenneth Mosman, May 11, 2026