- Home
- Density Test Report Report ID: 94234
- Edit Download Report
Density Test Report
Date :04/25/2026
Project No :2023C159
Client Company :CW Matthews
Arrival Time :04/25/2026
Onsite Hours :
Name of the Project :Airfield Repairs 2021-23
Project Location :HJAIA, Atlanta, GA
Weather :overcast
Departure Time :04/25/2026
ASEC Technician Name :Russell Hendrix
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 04/25/2026 | 1 | 11.9 | 125.4 | 2026-118 | 124.3 | 8.9 | 100.9 | 90 | D6938 | Pass |
| Location : | Area 4, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | QA proctor used 128.98 DD/ 7.5% Moisture. Pass / agreed with QA | Gauge Serial No. :38069 | ||||||||
| 04/25/2026 | 2 | 10.7 | 123.1 | 2026-118 | 124.3 | 8.9 | 99.0 | 90 | D6938 | Pass |
| Location : | Area 4, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | prooctor from QA used. Pass / agreed with QA 128.98 DD/ 7.5% Moisture | Gauge Serial No. :38069 | ||||||||
| 04/25/2026 | retest 1 | 16 | 104.1 | 2026-111 | 119.3 | 10.6 | 87.3 | 90 | D6938 | Fail |
| Location : | Area 4, Elv/Depth :First lift placed earlier | |||||||||
| Comment : | fail / QA in agreement. QA recommending mixing GAB in soil to lower moisture. | Gauge Serial No. :38069 | ||||||||
| 04/25/2026 | Retest 2 | 9.8 | 117.7 | 2026-111 | 119.3 | 10.6 | 98.7 | 90 | D6938 | Pass |
| Location : | Area 4, Elv/Depth :First lift placed earlier | |||||||||
| Comment : | Pass after mixing with GAB. QA in agreement | Gauge Serial No. :38069 | ||||||||
Technician Signature / DateRussell Hendrix, April 25, 2026
Reviewer Name / DateKenneth Mosman, May 25, 2026