Skip to content

Density Test Report

Date :04/25/2026
Project No :2023C159
Client Company :CW Matthews
Arrival Time :04/25/2026
Onsite Hours :
Name of the Project :Airfield Repairs 2021-23
Project Location :HJAIA, Atlanta, GA
Weather :overcast
Departure Time :04/25/2026
ASEC Technician Name :Russell Hendrix

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/25/2026 1 11.9 125.4 2026-118 124.3 8.9 100.9 90 D6938 Pass
Location : Area 4, Elv/Depth :1 foot below finished grade
Comment : QA proctor used 128.98 DD/ 7.5% Moisture. Pass / agreed with QA Gauge Serial No. :38069
04/25/2026 2 10.7 123.1 2026-118 124.3 8.9 99.0 90 D6938 Pass
Location : Area 4, Elv/Depth :1 foot below finished grade
Comment : prooctor from QA used. Pass / agreed with QA 128.98 DD/ 7.5% Moisture Gauge Serial No. :38069
04/25/2026 retest 1 16 104.1 2026-111 119.3 10.6 87.3 90 D6938 Fail
Location : Area 4, Elv/Depth :First lift placed earlier
Comment : fail / QA in agreement. QA recommending mixing GAB in soil to lower moisture. Gauge Serial No. :38069
04/25/2026 Retest 2 9.8 117.7 2026-111 119.3 10.6 98.7 90 D6938 Pass
Location : Area 4, Elv/Depth :First lift placed earlier
Comment : Pass after mixing with GAB. QA in agreement Gauge Serial No. :38069
Technician Signature / DateRussell Hendrix, April 25, 2026
Reviewer Name / DateKenneth Mosman, May 25, 2026