Skip to content

Density Test Report

Date :04/24/2026
Project No :2023C159
Client Company :CW Matthews
Arrival Time :04/24/2026
Onsite Hours :
Name of the Project :Airfield Repairs 2021-23
Project Location :HJAIA, Atlanta, GA
Weather :overcast
Departure Time :04/24/2026
ASEC Technician Name :Russell Hendrix

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/24/2026 1 17.3 96.8 2026-111 119.3 10.6 81.1 90 D6938 Fail
Location : Area 3, Elv/Depth :First lift after excavation
Comment : fail / QA in agreement. requested lowering moisture, recompact Gauge Serial No. :38069
Technician Signature / DateRussell Hendrix, April 24, 2026