Skip to content

Density Test Report

Date :04/27/2026
Project No :2023C159
Client Company :CW Matthews
Arrival Time :04/27/2026
Onsite Hours :
Name of the Project :Airfield Repairs 2021-23
Project Location :HJAIA, Atlanta, GA
Weather :overcast
Departure Time :04/27/2026
ASEC Technician Name :Russell Hendrix

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/27/2026 1 5.4 135.5 2026-120 130.9 6.0 103.5 95 D6938 Pass
Location : Area 3, Elv/Depth :at finished grade
Comment : Pass / QA in agreement (proctor used 140.0 WD / 5.0 % moisture) Gauge Serial No. :38069
04/27/2026 1 5.0 134.9 2026-119 136.8 8.0 98.6 95 D6938 Pass
Location : Area 2, Elv/Depth :at finished grade
Comment : Pass (QA in agreement. Proctor used 140 WD / 5.0 % moisture) Gauge Serial No. :38069
Technician Signature / DateRussell Hendrix, April 27, 2026
Reviewer Name / DateKenneth Mosman, May 25, 2026