Daily Field Report

Date :05/21/2026
Project No :2025C214
Client Company :Artisan
Arrival Time :05/21/2026 07:30
Onsite Hours :9:00
Name of the Project :NW Unit 4 BRIDGE (Materials Testing)
Project Location :Dallas
Weather :cloudy
Departure Time :05/21/2026 16:30
ASEC Technician Name :Clyde Smith

Observations/Finding

As requested, the site was visited by our AS Engineering and Consulting (ASEC) representative for the purpose of providing quality control inspection and testing services.  Visual observation techniques were employed to verify compliance with project drawing/specifications, applicable codes, and materials submittals. The following observations were observed on site this day.

On the above date our representative was on site to observe the wall contractor continue backfilling for the north side bridge abutment using hauled in materials. The soil materials were compacted in suitable lift thicknesses and density tests were performed using a Troxler Nuclear gauge model 3430, serial no. 91643. Compaction results were found to be suitable as per job specifications. The writer also observed undercutting for the crane pad removing wet organic materials to suitable stable materials. The contractor began backfilling undercut areas until a light rain event occurred. Remaining fill shall be observed after the rain event.

The writer observed proof-rolling of subbase stone at Nature Walk Boulevard between sanitary sewer manholes #5 and #10 and drives to Phase 1A and 1B using a loaded tandem dump truck loaded with 18.36 tons. The subbase appeared stable with no apparent movement under traffic and was suitable for asphalt paving. The proof-roll was also observed by Mr. Mike Kenner with Paulding County, and David with NWGP. Note that if severe rain occurs prior to paving it’s recommended to reobserve these subbase materials.

We appreciate the opportunity to be of service to you on this project. If you have any questions regarding this report, please feel free to contact us. We will be more than happy to discuss it with you.

Observing backfill at undercut crane pad

Compacting wall backfill

Probing undercut area at crane pad

Undercutting crane pad

Performing density tests at wall backfill

Recommended undercut area at crane pad

Proof rolling sub grade at crane pad to determine undercut

Placing fill at undercut crane pad.

Proof rolling of sub base stone at Nature Walk Pkwy.between sanitary sewer manhole # 5 and 10 and drives to Phase 1A and 1B

Showing depths for asphalt paving 3.5 inchs

Technician Signature / DateClyde Smith, May 21, 2026
Reviewer Name / DateKenneth Mosman, May 28, 2026