- Home
- Density Test Report Report ID: 95614
- Edit Download Report
Density Test Report
Date :06/24/2026
Project No :2025C216
Client Company :Artisan
Arrival Time :06/24/2026 11:00
Onsite Hours :01:30
Name of the Project :NW (Lots) Unit 4 PH 1A & 1B
Project Location :Dallas
Weather :Sunny
Departure Time :06/24/2026 12:30
ASEC Technician Name :Sean Willett
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 06/24/2026 | 1 | 11.7 | 99.8 | 2025-031 SP | 101.0 | 20.7 | 98.8 | 98 | D6938 | Pass |
| Location : | 4900-5000 roadway, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 06/24/2026 | 2 | 10.5 | 103.0 | 2025-031 SP | 101.0 | 20.7 | 102.0 | 98 | D6938 | Pass |
| Location : | 4900-5000 roadway, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 06/24/2026 | 3 | 12.4 | 103.0 | 2025-031 SP | 101.0 | 20.7 | 102.0 | 98 | D6938 | Pass |
| Location : | 4900-5000 roadway, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
Technician Signature / DateSean Willett, June 24, 2026
Reviewer Name / DateKenneth Mosman, July 07, 2026