Density Test Report

Date :06/30/2026
Project No :2026C125
Client Company :Lewis Contracting
Arrival Time :07/30/2026 08:00
Onsite Hours :05:00
Name of the Project :Pittman Park - Garibaldi St. Stormwater
Project Location :Atlanta
Weather :Sunny
Departure Time :07/30/2026 13:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
06/30/2026 1 4.7 134.9 2026-223 139.4 6.0 96.8 95 D6938 Pass
Location : Existing to D-3 roadway, Elv/Depth :at finished grade
Comment : New proctor of 139.4 @ 6.0% for GAB Gauge Serial No. :77-19952
06/30/2026 2 4.6 134.6 2026-223 139.4 6.0 96.6 95 D6938 Pass
Location : Existing to D-3 roadway, Elv/Depth :at finished grade
Comment : New proctor of 139.4 @ 6.0% for GAB Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, June 30, 2026
Reviewer Name / DateKenneth Mosman, July 06, 2026