- Home
- Density Test Report Report ID: 96076
- Edit Download Report
Density Test Report
Date :07/09/2026
Project No :2026C100
Client Company :Artisan
Arrival Time :07/09/2026 12:00
Onsite Hours :03:00
Name of the Project :Naturewalk PHASE 3 (PH 2 Extension) Lots
Project Location :Dallas
Weather :sunny
Departure Time :07/09/2026 15:00
ASEC Technician Name :Samara Simha Reddy Kandi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 07/09/2026 | 1 | 16.1 | 92.6 | Field proctor #6 | 98.0 | 17.2 | 94.5 | 95 | D6938 | Fail |
| Location : | Future lots, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | The affected area was re-compacted and requires follow-up density testing. | Gauge Serial No. :38069 | ||||||||
| 07/09/2026 | 2 | 15.8 | 91.8 | Field proctor #6 | 98.0 | 17.2 | 93.7 | 95 | D6938 | Fail |
| Location : | Future lots, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | The affected area was re-compacted and requires follow-up density testing. | Gauge Serial No. :38069 | ||||||||
| 07/09/2026 | 3 | 15.7 | 93.6 | Field proctor #6 | 98.0 | 17.2 | 95.5 | 95 | D6938 | Pass |
| Location : | Future lots, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 07/09/2026 | 4 | 17.1 | 92.1 | Field proctor #6 | 98.0 | 17.2 | 94.0 | 95 | D6938 | Fail |
| Location : | Future lots, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | The affected area was re-compacted and requires follow-up density testing. | Gauge Serial No. :38069 | ||||||||
Technician Signature / DateSamara Simha Reddy Kandi, July 9, 2026