Skip to content

Density Test Report

Date :08/14/2026
Project No :2026C101
Client Company :Artisan
Arrival Time :08/14/2026
Onsite Hours :
Name of the Project :Seven Hills PHASE 13, UNIT 3 Lots
Project Location :Dallas
Weather :sunny
Departure Time :08/14/2026
ASEC Technician Name :Russell Hendrix

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
08/14/2026 1 13.0 97.7 26443 101.3 19.4 96.4 95 D6938 Pass
Location : 100 feet from gas line, Elv/Depth :-16 feet below finish grade
Comment : Gauge Serial No. :92204
08/14/2026 2 12.9 131.0 26398 120.5 11.5 96.3 95 D6938 Pass
Location : 120 feet from Gas line, back of amenities, Elv/Depth :-16 feet below finish grade
Comment : Gauge Serial No. :92204
Technician Signature / DateRussell Hendrix, August 14, 2026
Reviewer Name / DateKenneth Mosman, August 18, 2026