- Home
- Density Test Report Report ID: 96907
- Edit Download Report
Density Test Report
Date :08/12/2026
Project No :2023C159
Client Company :CW Matthews
Arrival Time :08/12/2026 8:00
Onsite Hours :08:00
Name of the Project :Airfield Repairs 2021-23
Project Location :HJAIA, Atlanta, GA
Weather :clear and sunny
Departure Time :08/12/2026 16:00
ASEC Technician Name :Narayana Ganesh Undavalli
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 08/12/2026 | 1 | 17.0 | 109.2 | Field Proctor | 110.4 | 17.1 | 98.9 | 95 | D6938 | Pass |
| Location : | Taxiway golf - North slope drainage structure, Elv/Depth :4 ft below final grade | |||||||||
| Comment : | Gauge Serial No. :91487 | |||||||||
Technician Signature / DateNarayana Ganesh Undavalli, August 12, 2026