- Home
- Density Test Report Report ID: 97699
- Edit Download Report
Density Test Report
Date :09/16/2026
Project No :2026C101
Client Company :Artisan
Arrival Time :09/16/2026 07:30
Onsite Hours :10:00
Name of the Project :Seven Hills PHASE 13, UNIT 3 Lots
Project Location :Dallas
Weather :sunny
Departure Time :09/16/2026 17:30
ASEC Technician Name :Clyde Smith
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 09/16/2026 | 1 | 12.9 | 100.4 | 2025-033 SP | 104.0 | 16.2 | 96.5 | 95 | D6938 | Pass |
| Location : | Building Lot #10, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 09/16/2026 | 2 | 13.1 | 101.1 | 2025-033 SP | 104.0 | 16.2 | 97.2 | 95 | D6938 | Pass |
| Location : | Building Lot #10, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 09/16/2026 | 3 | 13.3 | 101.7 | 2025-033 SP | 104.0 | 16.2 | 97.8 | 95 | D6938 | Pass |
| Location : | Building Lot #11, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 09/16/2026 | 4 | 20.4 | 91.9 | 2025-032 SP | 94.9 | 25.0 | 96.8 | 95 | D6938 | Pass |
| Location : | Building Lot #11, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 09/16/2026 | 5 | 11.9 | 103.6 | 2025-035 SP | 107.8 | 13.0 | 96.1 | 95 | D6938 | Pass |
| Location : | Building Lot #12, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 09/16/2026 | 6 | 12.8 | 103.4 | 2025-035 SP | 107.8 | 13.0 | 95.9 | 95 | D6938 | Pass |
| Location : | Building Lot #12, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 09/16/2026 | 7 | 12.8 | 100.8 | 2025-033 SP | 104.0 | 16.2 | 96.9 | 95 | D6938 | Pass |
| Location : | Building Lot #13, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 09/16/2026 | 8 | 13.2 | 100.8 | 2025-033 SP | 104.0 | 16.2 | 96.9 | 95 | D6938 | Pass |
| Location : | Building Lot #13, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 09/16/2026 | 9 | 12.7 | 103.5 | 2025-035 SP | 107.8 | 13.0 | 96.0 | 95 | D6938 | Pass |
| Location : | Building Lot #14, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 09/16/2026 | 10 | 13.1 | 103.7 | 2025-035 SP | 107.8 | 13.0 | 96.2 | 95 | D6938 | Pass |
| Location : | Building Lot #14, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
Technician Signature / DateClyde Smith, September 16, 2026
Reviewer Name / DateKenneth Mosman, September 17, 2026