Date
*
Project Number
*
2024C217(Naturewalk - 7 Hills Amenities)
Name of the Project
*
Project Location
Client Company
*
Weather
Arrival Date
Arrival Time
Departure Date
Departure Time
Onsite Hours
ASEC Technician Name
solomon.cherie (Solomon Cherie)
Observations/Finding
Summary
*
Our AS Engineering & Consulting (ASEC) representative arrived on site to observe field activities. The following tasks were performed: Observed the placement of fill/grading for the Pickle Ball court today. Compaction tests were performed using a nuclear density gauge. Overall, the results of density testing found that fill compaction did not meet the project and ASTM requirements for compaction. In addition, proof-rolling displayed severe pumping and rutting along the area. Recommended scarification and aeration of the wet subgrade prior to recompaction. Please contact us if you have any questions regarding this report or of the density test results.
Upload Images
Image
Description
1
Picture depicting pumping during proof rolling
1