Date
*
Project Number
*
2025C281(Owen Mills - Owens Store Rd)
Name of the Project
*
Project Location
Client Company
*
Weather
Arrival Date
Arrival Time
Departure Date
Departure Time
Onsite Hours
ASEC Technician Name
sean.willett (Sean Willett)
Observations/Finding
Summary
*
<h3 data-start="622" data-end="644">FIELD OBSERVATIONS</h3> <p data-start="646" data-end="933">On the above date, an AS Engineering and Consulting, LLC (ASEC) representative visited the site at the contractor’s request to <strong data-start="773" data-end="841">observe earthwork operations and perform quality control testing</strong> in accordance with the project drawings, specifications, and approved materials submittals.</p> <p data-start="935" data-end="1175">The contractor was completing the <strong data-start="969" data-end="1017">final approximately 2 feet of fill placement</strong> along the <strong data-start="1028" data-end="1078">dam embankment located at the rear of the site</strong>. Fill was placed in <strong data-start="1099" data-end="1130">approximately 12-inch lifts</strong> and compacted using a <strong data-start="1153" data-end="1174">sheepsfoot roller</strong>.</p> <p data-start="1177" data-end="1465">Field <strong data-start="1183" data-end="1211">in-place density testing</strong> was conducted along the dam embankment. Fill performance was further evaluated by <strong data-start="1294" data-end="1355">observing loaded off-road haul trucks traversing the lift</strong>, which served as proofrolling. <strong data-start="1387" data-end="1427">No pumping, cracking, or instability</strong> was observed during these activities.</p> <p data-start="1467" data-end="1702">Following completion of the fill placement, the contractor proceeded with <strong data-start="1541" data-end="1594">topsoil placement in designated green space areas</strong> and implemented <strong data-start="1611" data-end="1640">rain preparation measures</strong> in anticipation of forecasted precipitation later in the day.</p>
Upload Images
Image
Description
1
dam
2
cut
3
cut
1
Add Row
Post Status custom
Validate Email
Visual
Code
Insert/edit link
Close
Enter the destination URL
URL
Link Text
Open link in a new tab
Or link to existing content
Search
No search term specified. Showing recent items.
Search or use up and down arrow keys to select an item.
Cancel