- Home
- Density Test Report Report ID: 1148
- This project is inactive from admin.Download Report
Density Test Report
Date :10/21/2020
Project No :
Client Company :DR Horton
Arrival Time :10/21/2020 09:30
Onsite Hours :06:00
Name of the Project :Monet Gardens
Project Location :River Road at Green Pastures Way, Ellenwood, GA
Weather :Sunny
Departure Time :10/21/2020 15:30
ASEC Technician Name :Ramchandra Mogulla
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
10/21/2020 | 1 | 19.8 | 89.8 | P-1 | 97.4 | 21 | 92.2 | 90 | D2937 | Pass |
Location : | Lot # 19, Elv/Depth :-7 feet | |||||||||
Comment : | ||||||||||
10/21/2020 | 2 | 17.9 | 93.4 | P-1 | 97.4 | 21 | 95.9 | 90 | D2937 | Pass |
Location : | Lot 18, Elv/Depth :-6 feet | |||||||||
Comment : | ||||||||||
10/21/2020 | 3 | 17.0 | 93.3 | P-1 | 97.4 | 21 | 95.8 | 90 | D2937 | Pass |
Location : | Lot 17, Elv/Depth :-5 feet | |||||||||
Comment : |
Technician Signature / DateRamchandra Mogulla, October 21, 2020
Reviewer Name / DateKenneth Mosman, December 10, 2021