Skip to content

Density Test Report

Date :11/04/2020
Project No :
Client Company :DR Horton
Arrival Time :11/04/2020 09:30
Onsite Hours :06:30
Name of the Project :Monet Gardens
Project Location :River Road at Green Pastures Way, Ellenwood, GA
Weather :Sunny
Departure Time :11/04/2020 16:00
ASEC Technician Name :Ramchandra Mogulla

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
11/04/2020 6 16.2 94.1 P-2 102.3 18.0 92.0 90 D2937 Pass
Location : Lot # 9, Elv/Depth :-9 feet
Comment :
11/04/2020 7 16.9 92.6 P-2 102.3 18.0 90.5 90 D2937 Pass
Location : Lot # 9 and pipe backfill (Storm drain), Elv/Depth :-9 feet
Comment :
Technician Signature / DateRamchandra Mogulla, November 4, 2020
Reviewer Name / DateKenneth Mosman, December 10, 2021