- Home
- Density Test Report Report ID: 1495
- This project is inactive from admin.Download Report
Density Test Report
Date :12/15/2020
Project No :
Client Company :DR Horton
Arrival Time :12/15/2020 09:00
Onsite Hours :06:00
Name of the Project :Monet Gardens
Project Location :River Road at Green Pastures Way, Ellenwood, GA
Weather :Sunny
Departure Time :12/15/2020 15:00
ASEC Technician Name :Dave Bek
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
12/15/2020 | 1 | 17.7 | 100.1 | P-1 | 97.4 | 21 | 102.8 | 98 | D2937 | Pass |
Location : | Sewer Line A (River Rd), Elv/Depth :3 feet below FF | |||||||||
Comment : |
Technician Signature / DateDave Bek, December 15, 2020
Reviewer Name / DateRamchandra Mogulla, January 07, 2021