Skip to content

Density Test Report

Date :10/22/2021
Project No :2021C073
Client Company :DR Horton West
Arrival Time :10/22/2021 9:30
Onsite Hours :9:00
Name of the Project :Tributary C2A
Project Location :Riverside Parkway, City of Douglasville, GA
Weather :Partly cloudy
Departure Time :10/22/2021 18:30
ASEC Technician Name :Christopher Burrow II

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/22/2021 1 26.8 114.1 P-01 93.9 22.6 95.8 95 D6938 Pass
Location : 50' from S1 in the direction of S0, Elv/Depth :-12 feet
Comment : Gauge Serial No. :38069
10/22/2021 2 27.1 114.5 P-01 93.9 22.6 96.0 95 D6938 Pass
Location : 150' from S1 in the direction of S0, Elv/Depth :-8 feet
Comment : Gauge Serial No. :38069
10/22/2021 3 27.5 113.4 P-01 93.9 22.6 94.7 95 D6938 Fail
Location : 50' from S1 in the direction of S0, Elv/Depth :-10 feet
Comment : Gauge Serial No. :38069
10/22/2021 4 26.7 115.1 P-01 93.9 22.6 96.7 95 D6938 Pass
Location : 150' from S1 in the direction of S0, Elv/Depth :-7 feet
Comment : Gauge Serial No. :38069
10/22/2021 5 24.7 115.8 P-01 93.9 22.6 98.9 95 D6938 Pass
Location : 50' from S1 in the direction of S0, Elv/Depth :-9 feet
Comment : Gauge Serial No. :38069
10/22/2021 6 24.6 114.6 P-01 93.9 22.6 98.0 95 D6938 Pass
Location : 150' from S1 in the direction of S0, Elv/Depth :-6 feet
Comment : Gauge Serial No. :38069
10/22/2021 7 24.8 113.8 P-01 93.9 22.6 97.1 95 D6938 Pass
Location : 50' from S1 in the direction of S0, Elv/Depth :-7 feet
Comment : Gauge Serial No. :38069
10/22/2021 8 26.1 114.6 P-01 93.9 22.6 96.8 95 D6938 Pass
Location : 150' from S1 in the direction of S0, Elv/Depth :-4 feet
Comment : Gauge Serial No. :38069
10/22/2021 9 26.2 114.7 P-01 93.9 22.6 96.8 95 D6938 Pass
Location : 50' from S1 in the direction of S0, Elv/Depth :-5
Comment : Gauge Serial No. :38069
10/22/2021 10 27.5 115.8 P-01 93.9 22.6 96.7 95 D6938 Pass
Location : 150' from S1 in the direction of S0, Elv/Depth :-3 feet
Comment : Gauge Serial No. :38069
10/22/2021 11 27.1 113.9 P-01 93.9 22.6 95.4 95 D6938 Pass
Location : 50' from S1 in the direction of S0, Elv/Depth :-2 feet
Comment : Gauge Serial No. :38069
10/22/2021 12 27.2 113.8 P-01 93.9 22.6 95.3 95 D6938 Pass
Location : 150' from S1 in the direction of S0, Elv/Depth :-2 feet
Comment : Gauge Serial No. :38069
10/22/2021 13 26.5 90.4 P-01 93.9 22.6 96.3 95 D6938 Pass
Location : 50' from S1 in the direction of S0, Elv/Depth :-1 feet
Comment : Gauge Serial No. :38069
10/22/2021 14 25.8 111.3 P-01 93.9 22.6 94.2 95 D6938 Fail
Location : 150' from S1 in the direction of S0, Elv/Depth :-1 feet
Comment : Gauge Serial No. :38069
10/22/2021 15 26.3 92.7 P-01 93.9 22.6 98.7 95 D6938 Pass
Location : 50' from S1 in the direction of S0, Elv/Depth :At final grade
Comment : Gauge Serial No. :38069
Technician Signature / DateChristopher Burrow II, October 22, 2021
Reviewer Name / DateRamchandra Mogulla, April 03, 2023