Density Test Report

Date :08/06/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :08/06/2021 07:30
Onsite Hours :10:30
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :08/06/2021 18:00
ASEC Technician Name :Christopher Burrow II

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
08/06/2021 1 16.3 97.7 P-3 103.0 18.1 94.9 95 D2937 Fail
Location : Center of road between lot 344 & 288, Elv/Depth :12’ below final grade
Comment :
08/06/2021 2 15.6 102.6 P-3 103.0 18.1 99.6 95 D2937 Pass
Location : Center of 347, Elv/Depth :10’ below final grade
Comment :
08/06/2021 3 28.0 85.5 P-1 85.8 31.0 99.7 95 D2937 Pass
Location : Center of road between lot 341 & 285, Elv/Depth :10’ below final grade
Comment :
08/06/2021 4 23.2 102.1 P-3 103.0 18.1 99.1 95 D2937 Pass
Location : Center of line between lot 295 and retention pond, Elv/Depth :6’ below final grade
Comment :
Technician Signature / DateChristopher Burrow II, August 6, 2021
Reviewer Name / DateRamchandra Mogulla, September 07, 2021