- Home
- Density Test Report Report ID: 33643
- This project is inactive from admin.Download Report
Density Test Report
Date :08/09/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :08/09/2021 08:00
Onsite Hours :06:00
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :08/09/2021 14:00
ASEC Technician Name :Christopher Burrow II
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
08/09/2021 | 1 | 37.7 | 80.8 | P-1 | 85.8 | 31.0 | 94.2 | 95 | D2937 | Fail |
Location : | Center of lot 283, Elv/Depth :9’ below final grade | |||||||||
Comment : |
Technician Signature / DateChristopher Burrow II, August 9, 2021
Reviewer Name / DateRamchandra Mogulla, September 07, 2021