Skip to content

Density Test Report

Date :08/09/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :08/09/2021 08:00
Onsite Hours :06:00
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :08/09/2021 14:00
ASEC Technician Name :Christopher Burrow II

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
08/09/2021 1 37.7 80.8 P-1 85.8 31.0 94.2 95 D2937 Fail
Location : Center of lot 283, Elv/Depth :9’ below final grade
Comment :
Technician Signature / DateChristopher Burrow II, August 9, 2021
Reviewer Name / DateRamchandra Mogulla, September 07, 2021