Density Test Report
Date :08/24/2021
Project No :2021C073
Client Company :DR Horton West
Arrival Time :08/24/2021 14:00
Onsite Hours :02:00
Name of the Project :Tributary C2A
Project Location :Riverside Parkway, City of Douglasville, GA
Weather :Partly cloudy
Departure Time :08/24/2021 16:00
ASEC Technician Name :Christopher Burrow II
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
08/24/2021 | 1 | 19.8 | 97.8 | P-01 | 93.9 | 22.6 | 104.2 | 95 | D2937 | Pass |
Location : | Center of lot 443, Elv/Depth :Final grade | |||||||||
Comment : | ||||||||||
08/24/2021 | 2 | 25.0 | 90.2 | P-03 | 90.5 | 25.7 | 99.7 | 95 | D2937 | Pass |
Location : | Center of lot 460, Elv/Depth :Final grade | |||||||||
Comment : |
Technician Signature / DateChristopher Burrow II, August 24, 2021
Reviewer Name / DateRamchandra Mogulla, March 29, 2023