Skip to content

Density Test Report

Date :08/24/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :08/24/2021 12:00
Onsite Hours :04:00
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :08/24/2021 16:00
ASEC Technician Name :Christopher Burrow II

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
08/24/2021 1 17.4 106.6 P-2 111.3 14.6 95.8 95 D2937 Pass
Location : Center of lot 286, Elv/Depth :7’ below final grade
Comment :
Technician Signature / DateChristopher Burrow II, August 24, 2021
Reviewer Name / DateRamchandra Mogulla, September 07, 2021