- Home
- Density Test Report Report ID: 33742
- This project is inactive from admin.Download Report
Density Test Report
Date :08/30/2021
Project No :2021C070
Client Company :CCG Constructors LLC (Century)
Arrival Time :08/30/2021 11:30
Onsite Hours :03:45
Name of the Project :Harmony Heights
Project Location :Mt. Olive Road at Brentwood Drive, Commerce, GA
Weather :sunny
Departure Time :08/30/2021 15:15
ASEC Technician Name :Russell Hendrix
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
08/30/2021 | 1 | 19.5 | 122.8 | P-01 | 102.0 | 16.6 | 100.8 | 95 | D6938 | Pass |
Location : | lot 1 , Elv/Depth :880 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
08/30/2021 | 2 | 17.7 | 116.2 | P-01 | 102.0 | 16.6 | 96.8 | 95 | D6938 | Pass |
Location : | lot 2, Elv/Depth :878 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
08/30/2021 | 3 | 17.2 | 99.6 | P-01 | 102.0 | 16.6 | 97.6 | 95 | D6938 | Pass |
Location : | lot 3, Elv/Depth :878 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
08/30/2021 | 4 | 17.2 | 101.1 | P-01 | 102.0 | 16.6 | 99.1 | 95 | D6938 | Pass |
Location : | lot 4, Elv/Depth :878 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
08/30/2021 | 5 | 19.9 | 101.2 | P-01 | 102.0 | 16.6 | 99.2 | 95 | D6938 | Pass |
Location : | lot 5, Elv/Depth :876 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
08/30/2021 | 6 | 21.2 | 121.2 | P-01 | 102.0 | 16.6 | 98.0 | 95 | D6938 | Pass |
Location : | lot 6, Elv/Depth :876 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
08/30/2021 | 7 | 19.2 | 121.4 | P-01 | 102.0 | 16.6 | 99.8 | 95 | D6938 | Pass |
Location : | lot 7, Elv/Depth :876 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
08/30/2021 | 8 | 20.7 | 98.7 | P-01 | 102.0 | 16.6 | 96.8 | 95 | D6938 | Pass |
Location : | lot 8, Elv/Depth :878 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
08/30/2021 | 9 | 16.5 | 111.7 | P-01 | 102.0 | 16.6 | 94.0 | 95 | D6938 | Fail |
Location : | lot 9, Elv/Depth :876 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
08/30/2021 | 10 | 19.4 | 103.2 | P-01 | 102.0 | 16.6 | 101.2 | 95 | D6938 | Pass |
Location : | lot 10, Elv/Depth :876 | |||||||||
Comment : | Gauge Serial No. :29588 |
Technician Signature / DateRussell Hendrix, August 30, 2021
Reviewer Name / DateRamchandra Mogulla, November 18, 2021