- Home
- Density Test Report Report ID: 33881
- This project is inactive from admin.Download Report
Density Test Report
Date :09/07/2021
Project No :2021C070
Client Company :CCG Constructors LLC (Century)
Arrival Time :09/07/2021 07:30
Onsite Hours :04:30
Name of the Project :Harmony Heights
Project Location :Mt. Olive Road at Brentwood Drive, Commerce, GA
Weather :cloudy
Departure Time :09/07/2021 12:00
ASEC Technician Name :Russell Hendrix
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
09/07/2021 | 1 | 18.7 | 105.5 | P-02 | 105.6 | 16.6 | 99.9 | 95 | D6938 | Pass |
Location : | Lot 23, Elv/Depth :840 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
09/07/2021 | 2 | 20.3 | 127.3 | P-02 | 105.6 | 16.6 | 100.2 | 95 | D6938 | Pass |
Location : | 24, Elv/Depth :840 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
09/07/2021 | 3 | 19.6 | 104.2 | P-02 | 105.6 | 16.6 | 98.7 | 95 | D6938 | Pass |
Location : | Lot 25, Elv/Depth :840 | |||||||||
Comment : | It was discussed with the Cat dozer operator about making smaller lifts . Initially the lift was 16", but was addressed and changed to 8" lifts. This was appropriate for the compactor BW211 PD-50. | Gauge Serial No. :29588 | ||||||||
09/07/2021 | 4 | 20.6 | 102.2 | P-02 | 105.6 | 16.6 | 96.8 | 95 | D6938 | Pass |
Location : | Lot 23, Elv/Depth :844 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
09/07/2021 | 5 | 20.3 | 107.0 | P-02 | 105.6 | 16.6 | 101.3 | 95 | D6938 | Pass |
Location : | Lot 24, Elv/Depth :844 | |||||||||
Comment : | Gauge Serial No. :29588 | |||||||||
09/07/2021 | 6 | 18.6 | 97.6 | P-01 | 102.0 | 16.6 | 95.7 | 95 | D6938 | Pass |
Location : | Lot 25, Elv/Depth :846 | |||||||||
Comment : | Discussed with compactor Operator to make more passes in between lifts. Foreman was offsite at the time. | Gauge Serial No. :29588 | ||||||||
09/07/2021 | 7 | 21.6 | 98.0 | P-01 | 102.0 | 16.6 | 96.1 | 95 | D6938 | Pass |
Location : | Lot 26, Elv/Depth :846 | |||||||||
Comment : | Started raining during this test. Operations ceased. | Gauge Serial No. :29588 |
Technician Signature / DateRussell Hendrix, September 7, 2021
Reviewer Name / DateRamchandra Mogulla, November 18, 2021