Skip to content

Density Test Report

Date :09/02/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :09/02/2021 09:30
Onsite Hours :08:30
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :09/02/2021 18:00
ASEC Technician Name :Christopher Burrow II

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
09/02/2021 1 18.1 99.5 P-3 103.0 18.1 96.6 95 D2937 Pass
Location : Center rear lot 317, Elv/Depth :16’ below grade
Comment :
09/02/2021 2 19.1 98.9 P-3 103.0 18.1 96.0 95 D2937 Pass
Location : Center lot 300, Elv/Depth :10’ below grade
Comment :
09/02/2021 3 16.7 106.4 P-2 111.3 14.6 95.6 95 D2937 Pass
Location : Rear center lot 299, Elv/Depth :11’ below grade
Comment :
09/02/2021 4 14.1 102.0 P-3 103.0 18.1 99.0 95 D2937 Pass
Location : Center between lots 318 and 319, Elv/Depth :15’ below grade
Comment :
Technician Signature / DateChristopher Burrow II, September 2, 2021
Reviewer Name / DateRamchandra Mogulla, October 13, 2021