- Home
- Density Test Report Report ID: 33946
- This project is inactive from admin.Download Report
Density Test Report
Date :09/03/2021
Project No :2021C073
Client Company :DR Horton West
Arrival Time :09/03/2021 07:30
Onsite Hours :04:00
Name of the Project :Tributary C2A
Project Location :Riverside Parkway, City of Douglasville, GA
Weather :Partly cloudy
Departure Time :09/03/2021 11:30
ASEC Technician Name :Christopher Burrow II
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
09/03/2021 | 1 | 23.2 | 89.8 | P-01 | 93.9 | 22.6 | 95.6 | 95 | D2937 | Pass |
Location : | Center of lot 419, Elv/Depth :1’ below grade | |||||||||
Comment : | ||||||||||
09/03/2021 | 2 | 21.2 | 90.8 | P-01 | 93.9 | 22.6 | 96.7 | 95 | D2937 | Pass |
Location : | Center of lot 422, Elv/Depth :Final grade | |||||||||
Comment : |
Technician Signature / DateChristopher Burrow II, September 3, 2021
Reviewer Name / DateRamchandra Mogulla, March 29, 2023