Density Test Report

Date :09/07/2021
Project No :2021C073
Client Company :DR Horton West
Arrival Time :09/07/2021 11:30
Onsite Hours :04:00
Name of the Project :Tributary C2A
Project Location :Riverside Parkway, City of Douglasville, GA
Weather :Partly cloudy
Departure Time :09/07/2021 15:30
ASEC Technician Name :Christopher Burrow II

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
09/07/2021 1 20.5 89.2 P-03 90.5 25.7 98.6 95 D2937 Pass
Location : Center of road between lot 439 and 430, Elv/Depth :4’ below final grade
Comment :
09/07/2021 2 20.7 90.6 P-03 90.5 25.7 100.1 95 D2937 Pass
Location : Front center of lot 439, Elv/Depth :3’ below final grade
Comment :
09/07/2021 3 22.7 95.5 P-01 93.9 22.6 101.7 95 D2937 Pass
Location : Front center of lot 430, Elv/Depth :2’ below final grade
Comment :
Technician Signature / DateChristopher Burrow II, September 7, 2021
Reviewer Name / DateRamchandra Mogulla, March 29, 2023