- Home
- Density Test Report Report ID: 33957
- This project is inactive from admin.Download Report
Density Test Report
Date :09/07/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :09/07/2021 08:00
Onsite Hours :03:30
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :09/07/2021 11:30
ASEC Technician Name :Christopher Burrow II
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
09/07/2021 | 1 | 19.5 | 99.2 | P-3 | 103.0 | 18.1 | 96.3 | 95 | D2937 | Pass |
Location : | Center of lot 347, Elv/Depth :4’ below final grade | |||||||||
Comment : |
Technician Signature / DateChristopher Burrow II, September 7, 2021
Reviewer Name / DateRamchandra Mogulla, October 13, 2021