- Home
- Density Test Report Report ID: 33962
- This project is inactive from admin.Download Report
Density Test Report
Date :09/09/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :09/09/2021 13:30
Onsite Hours :04:00
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :09/09/2021 17:30
ASEC Technician Name :Christopher Burrow II
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
09/09/2021 | 1 | 16.6 | 106.0 | P-2 | 111.3 | 14.6 | 95.2 | 95 | D2937 | Pass |
Location : | Center of lot 347, Elv/Depth :6’ below final grade | |||||||||
Comment : |
Technician Signature / DateChristopher Burrow II, September 9, 2021
Reviewer Name / DateRamchandra Mogulla, October 13, 2021