Skip to content

Density Test Report

Date :09/15/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :09/15/2021 08:30
Onsite Hours :04:30
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :09/15/2021 13:00
ASEC Technician Name :Christopher Burrow II

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
09/15/2021 1 16.4 106.4 P-2 111.3 14.6 95.6 95 D2937 Pass
Location : Center of lot 347, Elv/Depth :3’ below final grade
Comment :
09/15/2021 2 15.4 112.1 P-2 111.3 14.6 100.7 95 D2937 Pass
Location : Center of lot 293, Elv/Depth :3’ below final grade
Comment : Light rain during the test
Technician Signature / DateChristopher Burrow II, September 15, 2021
Reviewer Name / DateRamchandra Mogulla, October 13, 2021