- Home
- Density Test Report Report ID: 34325
- This project is inactive from admin.Download Report
Density Test Report
Date :09/29/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :09/29/2021 16:00
Onsite Hours :01:30
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :09/29/2021 17:30
ASEC Technician Name :Christopher Burrow II
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
09/29/2021 | 1 | 15.5 | 119.3 | P-2 | 111.3 | 14.6 | 107.2 | 100 | D6938 | Pass |
Location : | Center of lot 286, Elv/Depth :2’ below final grade | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
09/29/2021 | 2 | 17.6 | 113.8 | P-2 | 111.3 | 14.6 | 102.2 | 100 | D6938 | Pass |
Location : | Center of road between 286 and 293, Elv/Depth :2’ below final grade | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
09/29/2021 | 3 | 18.5 | 118.0 | P-2 | 111.3 | 14.6 | 106.0 | 100 | D6938 | Pass |
Location : | 30’ from A2-CB Drain, Elv/Depth :4’ below final grade | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
09/29/2021 | 4 | 26.5 | 94.6 | P-3 | 103.0 | 18.1 | 91.8 | 100 | D6938 | Fail |
Location : | 60’ from A2-CB drain, Elv/Depth :4’below final grade | |||||||||
Comment : | Area was recompacted after testing | Gauge Serial No. :38069 |
Technician Signature / DateChristopher Burrow II, September 29, 2021
Reviewer Name / DateKenneth Mosman, December 04, 2021