Skip to content

Daily Field Report

Date :11/12/2021
Project No :2020C007
Client Company :Pulte Group
Arrival Time :10/11/2021 07:00
Onsite Hours :02:00
Name of the Project :Winslow at Brookstone
Project Location :6156 Collins Road, Acworth, GA 30101
Weather :sunny / 61 degrees
Departure Time :10/11/2021 09:00
ASEC Technician Name :Russell Hendrix

Observations/Finding

The site was visited by the undersigned AS Engineering and Consulting (ASEC) representative for the purpose of providing quality control inspection and testing services. Visual observation techniques were employed to assure compliance with project drawings/specifications, applicable codes, and materials submittals. 

The footing for Lot # 25 for Winslow @ Brookstone was inspected in preparation for concrete placement.  A visual inspection, as well as a DCP test was conducted.  The footing for Lot #25 appeared suitable for concrete placement.  Please find the attached DCP report.

DCP TEST DATA SHEET
                         
Project Name: Winslow   Date: 10/11/21
Project Number: 2020C007   Technician: Russ Hendrix
Project Location: Lot #25
     
                         
DCP LOCATION:
Lot #, North/South/Center etc
#25 Footing   DCP LOCATION:
Lot #, North/South/Center etc
 
     
                         
Depth
(feet)
Set
2″
N
1.75″
Description   Depth
(feet)
Set
2″
N
1.75″
Description
1   14 Red fine Sandy silt   1      
2   10 Red fine Sandy silt   2      
3   8 Grey Silty fine sand   3      
4   7 Grey Silty fine sand   4      
5   8 Red Silty Clay   5      
6   9 Red Silty Clay   6      
7         7      
8         8      
9         9      
10         10      
Technician Signature / DateRussell Hendrix, November 12, 2021
Reviewer Name / DateKenneth Mosman, December 15, 2021