Skip to content

Density Test Report

Date :10/16/2021
Project No :2021C073
Client Company :DR Horton West
Arrival Time :10/16/2021 10:00
Onsite Hours :03:00
Name of the Project :Tributary C2A
Project Location :Riverside Parkway, City of Douglasville, GA
Weather :Partly Cloudy
Departure Time :10/16/2021 13:00
ASEC Technician Name :Christopher Burrow II

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/16/2021 1 18.7 91.8 P-01 93.9 22.6 97.8 95 D6938 Pass
Location : Sewer lateral lot 429, Elv/Depth :4’ Below final grade
Comment : Gauge Serial No. :38069
10/16/2021 2 20.9 93.3 P-01 93.9 22.6 99.4 95 D6938 Pass
Location : Manhole S6, Elv/Depth :5’ Below final grade
Comment : Gauge Serial No. :38069
10/16/2021 3 24.4 84.3 P-04 88.5 28.4 95.3 95 D6938 Pass
Location : Between manhole S6 And next manhole, Elv/Depth :6’ below final grade
Comment : Gauge Serial No. :38069
10/16/2021 4 17.4 100.5 P-01 93.9 22.6 107.0 95 D6938 Pass
Location : Sewer Lateral lot 429, Elv/Depth :3’ below final grade
Comment : Gauge Serial No. :38069
10/16/2021 5 20.6 95.1 P-01 93.9 22.6 101.3 95 D6938 Pass
Location : manhole S6, Elv/Depth :4’ below final grade
Comment : Gauge Serial No. :38069
Technician Signature / DateChristopher Burrow II, October 16, 2021
Reviewer Name / DateKenneth Mosman, December 09, 2021