Skip to content

Density Test Report

Date :10/16/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :10/16/2021 13:00
Onsite Hours :02:30
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :10/16/2021 15:30
ASEC Technician Name :Christopher Burrow II

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/16/2021 1 16.2 94.7 P-1 85.8 31.0 110.4 95 D6938 Pass
Location : Center of lot 284, Elv/Depth :1’ below final grade
Comment : Gauge Serial No. :38069
10/16/2021 2 20.4 94.0 P-1 85.8 31.0 109.6 95 D6938 Pass
Location : Center of lot 285, Elv/Depth :1’ below final grade
Comment : Gauge Serial No. :38069
10/16/2021 3 22 99.6 P-3 103.0 18.1 96.7 95 D6938 Pass
Location : Center of lot 340, Elv/Depth :1’ below final grade
Comment : Gauge Serial No. :38069
10/16/2021 4 14.9 98.4 P-3 103.0 18.1 95.5 95 D6938 Pass
Location : Center of lot 341, Elv/Depth :1’ below final grade
Comment : Gauge Serial No. :38069
Technician Signature / DateChristopher Burrow II, October 16, 2021
Reviewer Name / DateKenneth Mosman, December 04, 2021