Skip to content

Density Test Report

Date :10/19/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :10/19/2021 18:00
Onsite Hours :01:00
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :10/19/2021 19:00
ASEC Technician Name :Christopher Burrow II

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/19/2021 1 12.6 100.3 P-3 103.0 18.1 97.4 95 D6938 Pass
Location : Center of lot 285, Elv/Depth :Final grade
Comment : Gauge Serial No. :38069
10/19/2021 2 17.1 92.3 P-1 85.8 31.0 107.6 95 D6938 Pass
Location : Center of lot 286, Elv/Depth :Final grade
Comment : Gauge Serial No. :38069
Technician Signature / DateChristopher Burrow II, October 19, 2021
Reviewer Name / DateKenneth Mosman, December 04, 2021