- Home
- Density Test Report Report ID: 34484
- This project is inactive from admin.Download Report
Density Test Report
Date :10/25/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :10/25/2021 12:30
Onsite Hours :03:30
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :10/25/2021 16:00
ASEC Technician Name :Christopher Burrow II
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
10/25/2021 | 1 | 13.7 | 104.8 | P-3 | 103.0 | 18.1 | 101.7 | 95 | D2937 | Pass |
Location : | Center of lot 283, Elv/Depth :Final grade | |||||||||
Comment : | ||||||||||
10/25/2021 | 2 | 17.2 | 100.0 | P-3 | 103.0 | 18.1 | 97.1 | 95 | D2937 | Pass |
Location : | Center of lot 339, Elv/Depth :Final grade | |||||||||
Comment : |
Technician Signature / DateChristopher Burrow II, October 25, 2021
Reviewer Name / DateKenneth Mosman, December 04, 2021