Skip to content

Density Test Report

Date :10/27/2021
Project No :2021C073
Client Company :DR Horton West
Arrival Time :10/27/2021 15:00
Onsite Hours :02:00
Name of the Project :Tributary C2A
Project Location :Riverside Parkway, City of Douglasville, GA
Weather :Partly cloudy
Departure Time :10/27/2021 17:00
ASEC Technician Name :Christopher Burrow II

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/27/2021 1 17.6 89.0 P-04 88.5 28.4 100.6 95 D2937 Pass
Location : Manhole S-2, Elv/Depth :Final grade
Comment :
10/27/2021 2 15.4 93.8 P-01 93.9 22.6 99.9 95 D2937 Pass
Location : Manhole S-3, Elv/Depth :Final grade
Comment :
10/27/2021 3 14.0 111.1 P-02 116.9 14.7 95.0 95 D2937 Fail
Location : Manhole B-1, Elv/Depth :Final grade
Comment :
10/27/2021 4 21.9 86.6 P-04 88.5 28.4 97.9 95 D2937 Pass
Location : Manhole s-6, Elv/Depth :Final grade
Comment :
Technician Signature / DateChristopher Burrow II, October 27, 2021
Reviewer Name / DateKenneth Mosman, December 09, 2021