Skip to content

Density Test Report

Date :11/01/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :11/01/2021 16:00
Onsite Hours :02:30
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :11/01/2021 18:30
ASEC Technician Name :Christopher Burrow II

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
11/01/2021 1 18.1 102.8 P-3 103.0 18.1 99.8 95 D6938 Pass
Location : Road in front of lot 293, Elv/Depth :Final grade
Comment : Gauge Serial No. :38069
11/01/2021 2 19.5 100.1 P-3 103.0 18.1 97.2 95 D6938 Pass
Location : Road in front of lot 292, Elv/Depth :Final grade
Comment : Gauge Serial No. :38069
11/01/2021 3 17.3 105.7 P-2 111.3 14.6 95.0 95 D6938 Fail
Location : Road in front of lot 291, Elv/Depth :1’ below final grade
Comment : Gauge Serial No. :38069
11/01/2021 4 19.3 97.8 P-3 103.0 18.1 95.0 95 D6938 Fail
Location : Road in front of lot 290, Elv/Depth :2’ below final grade
Comment : Gauge Serial No. :38069
11/01/2021 5 22.2 100.2 P-3 103.0 18.1 97.3 95 D6938 Pass
Location : Road in front of lot 289, Elv/Depth :4’ below final grade
Comment : Gauge Serial No. :38069
Technician Signature / DateChristopher Burrow II, November 1, 2021
Reviewer Name / DateKenneth Mosman, December 06, 2021