Skip to content

Density Test Report

Date :11/02/2021
Project No :2021C073
Client Company :DR Horton West
Arrival Time :11/02/2021 12:00
Onsite Hours :02:30
Name of the Project :Tributary C2A
Project Location :Riverside Parkway, City of Douglasville, GA
Weather :Partly cloudy
Departure Time :11/02/2021 14:30
ASEC Technician Name :Christopher Burrow II

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
11/02/2021 1 19.8 96.4 P-01 93.9 22.6 102.7 95 D6938 Pass
Location : Manhole A4, Elv/Depth :6’ below final grade
Comment : Gauge Serial No. :38069
11/02/2021 2 22.3 84.9 P-04 88.5 28.4 95.9 95 D6938 Pass
Location : Manhole A5, Elv/Depth :6’ below final grade
Comment : Gauge Serial No. :38069
Technician Signature / DateChristopher Burrow II, November 2, 2021
Reviewer Name / DateKenneth Mosman, December 10, 2021