- Home
- Density Test Report Report ID: 34514
- This project is inactive from admin.Download Report
Density Test Report
Date :11/11/2021
Project No :2021C073
Client Company :DR Horton West
Arrival Time :11/11/2021 11:30
Onsite Hours :03:00
Name of the Project :Tributary C2A
Project Location :Riverside Parkway, City of Douglasville, GA
Weather :Partly Cloudy
Departure Time :11/11/2021 14:30
ASEC Technician Name :Christopher Burrow II
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
11/11/2021 | 1 | 18.8 | 98.1 | P-01 | 93.9 | 22.6 | 104.5 | 95 | D6938 | Pass |
Location : | Storm drainpipe behind Lot #450, Elv/Depth :Final grade | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
11/11/2021 | 2 | 9.9 | 122.0 | P-02 | 116.9 | 14.7 | 95.0 | 95 | D6938 | Fail |
Location : | Storm drainpipe behind Lot #451, Elv/Depth :Final grade | |||||||||
Comment : | Gauge Serial No. :38069 |
Technician Signature / DateChristopher Burrow II, November 11, 2021
Reviewer Name / DateKenneth Mosman, December 15, 2021