Skip to content

Density Test Report

Date :11/11/2021
Project No :2021C073
Client Company :DR Horton West
Arrival Time :11/11/2021 11:30
Onsite Hours :03:00
Name of the Project :Tributary C2A
Project Location :Riverside Parkway, City of Douglasville, GA
Weather :Partly Cloudy
Departure Time :11/11/2021 14:30
ASEC Technician Name :Christopher Burrow II

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
11/11/2021 1 18.8 98.1 P-01 93.9 22.6 104.5 95 D6938 Pass
Location : Storm drainpipe behind Lot #450, Elv/Depth :Final grade
Comment : Gauge Serial No. :38069
11/11/2021 2 9.9 122.0 P-02 116.9 14.7 95.0 95 D6938 Fail
Location : Storm drainpipe behind Lot #451, Elv/Depth :Final grade
Comment : Gauge Serial No. :38069
Technician Signature / DateChristopher Burrow II, November 11, 2021
Reviewer Name / DateKenneth Mosman, December 15, 2021