Daily Field Report

Date :12/22/2021
Project No :2021C060
Client Company :Pulte Group
Arrival Time :12/22/2021 07:30
Onsite Hours :02:00
Name of the Project :Suncity - Peachtree
Project Location :Griffin, GA
Weather :Cloudy
Departure Time :12/22/2021 09:30
ASEC Technician Name :Timothy Nevills

Observations/Finding

An ASEC engineering technician arrived onsite as requested to perform an evaluation of shallow foundation subgrade conditions of footings located in the following location:

Suncity, Peachtree, Expedition Pod#17, Lot #3.

This evaluation was performed using a hand auger, dynamic cone penetrometer, and small diameter pro rod.

After conducting foundation bearing tests in the referenced footing areas, all referenced footings were found to have a soil bearing capacity of 2000 psf.

If foundation soils become wet prior to concrete placement, it should be reevaluated by a geotechnical engineer or qualified technician. All loose fall-in soils or debris should be removed from the footings prior to concrete placement.

 

Lot #3

DCP testing performed

Technician Signature / DateTimothy Nevills, December 22, 2021
Reviewer Name / DateKenneth Mosman, December 27, 2021