Skip to content

Density Test Report

Date :01/25/2022
Project No :2021C082
Client Company :CCG Constructors LLC (Century)
Arrival Time :01/15/2022 08:30
Onsite Hours :04:30
Name of the Project :Estates at Old Friendship
Project Location :Buford, GA
Weather :40 cloudy
Departure Time :01/15/2022 13:00
ASEC Technician Name :Russell Hendrix

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
01/15/2022 1 21.5 82.3 P-2 102.2 20.3 80.5 95 D6938 Fail
Location : A7-A71, Elv/Depth :+2
Comment : This was a 24 inch lift compacted by Sct3 Wacker Neusom. Gauge Serial No. :38069
01/15/2022 2 25.4 76.9 P-2 102.2 20.3 75.2 95 D6938 Fail
Location : A7-A71, Elv/Depth :+3
Comment : Discussed with foreman and operator (Tito). Moisture content too high and too large a loose lift placed to achieve compaction. Soil removed. Gauge Serial No. :38069
01/15/2022 3 22.2 81.3 P-2 102.2 20.3 79.5 95 D6938 Fail
Location : A7-A71, Elv/Depth :+2
Comment : Gauge Serial No. :38069
01/15/2022 4 24 75.2 P-2 102.2 20.3 73.6 95 D6938 Fail
Location : A7-A71, Elv/Depth :+2
Comment : Discussed with Bill Bernard who stated remedial work would be addressed at a later time. Gauge Serial No. :38069
Technician Signature / DateRussell Hendrix, January 25, 2022
Reviewer Name / DateKenneth Mosman, February 16, 2023