- Home
- Density Test Report Report ID: 53119
- This project is inactive from admin.Download Report
Density Test Report
Date :02/20/2022
Project No :2021C082
Client Company :CCG Constructors LLC (Century)
Arrival Time :01/27/2022 10:00
Onsite Hours :07:00
Name of the Project :Estates at Old Friendship
Project Location :Buford, GA
Weather :34 / sunny
Departure Time :01/27/2022 17:00
ASEC Technician Name :Russell Hendrix
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
01/27/2022 | 1 | 15.9 | 102.5 | P-1 | 109.6 | 15.7 | 93.5 | 95 | D6938 | Fail |
Location : | 14+00 main road @ detention pond, Elv/Depth :+1 | |||||||||
Comment : | Gauge Serial No. :36089 | |||||||||
01/27/2022 | 2 | 15.2 | 93.1 | P-1 | 109.6 | 15.7 | 84.9 | 95 | D6938 | Fail |
Location : | 14+00, Elv/Depth :+1 | |||||||||
Comment : | This was a retest of same location. | Gauge Serial No. :36089 | ||||||||
D6938 | Fail | |||||||||
Location : | , Elv/Depth : | |||||||||
Comment : | Gauge Serial No. : |
Technician Signature / DateRussell Hendrix, February 20, 2022
Reviewer Name / DateKenneth Mosman, February 16, 2023