- Home
- Density Test Report Report ID: 53272
- This project is inactive from admin.Download Report
Density Test Report
Date :02/18/2022
Project No :2021C078
Client Company :CCG Constructors LLC (Century)
Arrival Time :02/18/2022
Onsite Hours :
Name of the Project :Pickens Landing Development
Project Location :Dacula, GA
Weather :41 cloudy
Departure Time :03/18/2022
ASEC Technician Name :Russell Hendrix
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
02/18/2022 | 1 | 30.9 | 69.4 | P-5 | 102.4 | 17.8 | 67.8 | 95 | D6938 | Fail |
Location : | Lot #37 (1+00 ), Elv/Depth :968 | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
02/18/2022 | 2 | 33 | 66.9 | P-5 | 102.4 | 17.8 | 65.3 | 95 | D6938 | Fail |
Location : | Lot #37 (1+00), Elv/Depth :969 | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
02/18/2022 | 3 | 28.8 | 70.2 | P-5 | 102.4 | 17.8 | 68.6 | 95 | D6938 | Fail |
Location : | Lot #37(1+00), Elv/Depth :970 | |||||||||
Comment : | Gauge Serial No. :38069 |
Technician Signature / DateRussell Hendrix, February 18, 2022
Reviewer Name / DateRamchandra Mogulla, December 12, 2022